国内精品国产三级国产在线专_欧美日韩在线播放一区二区_成人xxxx视频_欧美激情视频一区_色女人综合av_久久久亚洲影院_久久久久久九九_成人免费网站在线_日韩美女毛茸茸_狠狠干一区二区

Links
Contact Info.
  • Address:山東省青島市黃島區(qū)長江西路66號
  • Zip:266580
  • Tel:0532-86983500
  • Fax:
  • Email:[email protected]
Current Location :> Home > Publications > Text
Global Sensitivity Analysis of Occupant Egress Safety Model.
writer:De-peng, Kong, L. U. Shou-xiang, and L. O. Sm.
keywords:life safety, occupant egress, global sensitivity analysis, building fire
source:期刊
specific source:Procedia Engineering no. 11:179-184.
Issue time:2011年
Identification of the important factors for the occupant egress safety under building fire is important. In order to achieve this goal, a global sensitivity analysis method, Fourier Amplitude Sensitivity Test (FAST), was instead of the local sensitivity analysis to indentify the important factors for the safe evacuation level under building fire. The equation for safe egress level under building fire was determined by a series of empirical formulas. The result indicates that uncertainty of CFAST model has the dominating influence on the safety egress level while uncertainties associated with exit flow rate and population density have little influence. The relative differences between the first order sensitivity indies and the total sensitivity indies indicate that the interaction between fire growth rate and other factors has the largest influence on the safety egress level.